Insulation tube — DACELLFLEX
DACELLFLEX®

Insulation tube

Closed-cell NBR tube produced by continuous gel foaming, for copper and steel pipework in cooling and heating systems. Supplied in Class B and Class 0.

  • ID 6–89 mm, wall 6–50 mm
  • λ 0.030 W/(m·K) at 0 °C
  • Self-extinguishing, OI ≥ 32 %
  • Class B and Class 0
Ask for a price on this item

Insulation tube — technical data

PropertyClass BClass 0
same values
Cell structureClosed cell—
MaterialNBR / EPDM—
Density65 kg/m³ standard · 55–90 kg/m³ to order—
Thermal conductivity λ at −20 / 0 / +40 °C0.030 / 0.032 / 0.037 W/(m·K)0.030 / 0.032 / 0.037 W/(m·K)
Water vapour permeability1.96 × 10⁻¹¹ g/(m·s·Pa)—
Moisture resistance factor μ≥ 10,000—
Oxygen index≥ 32 %—
Flammability / smoke densitySelf-extinguishing / smoke density 25–50—
Water absorption≤ 5 %—
Service temperature−57 °C to +125 °C—
Flexibility / ozone resistanceExcellent / no crack—
Standard length1.83 m
Carton1850 × 320 × 360 mm

Values are nominal production figures, tested per batch. Density, wall thickness and colour are produced to the customer's specification.

— means the value is identical for Class B and Class 0.

Inner diameter 6–89 mm (1/4″–3-1/2″) · wall thickness 6–50 mm (1/4″–2″). Intermediate sizes produced on request.

Where this tube is used

The same closed-cell NBR tube is specified across four very different duty ranges. What changes is the wall thickness and the jacket — not the material.

Chilled water and DX lines, +4 to +12 °C

The common case, and the one that fails first when the material is wrong. A chilled line sits below the dew point of most plant rooms for much of the year, so the insulation surface has to stay above it. Closed cells plus a moisture resistance factor of μ ≥ 10,000 keep water vapour from travelling through the wall and condensing against the cold pipe — the mechanism that turns a cheap open-cell or PE product into a wet, dripping line within one season.

Refrigerant suction lines, −40 to +10 °C

Service temperature of the material is −57 °C to +125 °C, so suction lines are inside the range with margin. The flexible closed-cell structure is what matters here: it follows bends and offsets without cracking, and it stays flexible at low temperature instead of going brittle the way rigid foams do.

Heating and domestic hot water, up to +125 °C

Thermal conductivity rises with temperature — 0.030 W/(m·K) at −20 °C, 0.032 at 0 °C, 0.037 at +40 °C — so a wall thickness sized on the cold figure will under-perform on a hot line. Size hot lines on the λ at the actual mean temperature, not on the catalogue's headline number.

Heat pump and solar thermal pipework, outdoor

The material handles the temperature; it does not handle ultraviolet. Outdoors, the tube must be protected — aluminium foil facing, a painted finish, or a metal jacket — otherwise the surface degrades in a season or two. Say so in the specification rather than discovering it on site.

Condensate lines, duct connections and AHU tails

Short runs, awkward geometry, frequent direction changes. Tube is cut and glued on site, so the joint quality depends on the installer: a 1 mm gap at a joint is a cold bridge and a future drip.

How to specify the wall thickness

Thickness is not a catalogue decision — it is an output of four numbers about your line. Give us these and we return the wall thickness and the class that meets your code:

If the wall is undersized the surface drops below the dew point and the line runs wet: insulation becomes a reservoir, corrosion under insulation starts, and the drip stains the ceiling below. Over-sizing costs foam and eats the clearance in a plant room. It is worth ten minutes to size it once.

How the wall thickness is calculated →

Installation points that decide whether it works

Questions buyers ask before ordering

What wall thickness do I need for a chilled water pipe?

It depends on pipe diameter, the coldest medium temperature, and the ambient temperature and humidity of the space — the wall has to keep the insulation surface above the dew point. Send us those four numbers and we return the wall thickness and the class for your standard. Sizes in the standard range go from 6 mm to 89 mm inside diameter with wall from 6 mm to 50 mm.

Can the tube be installed outdoors?

The material is rated −57 °C to +125 °C, so temperature is not the limit — ultraviolet is. Outdoors the tube needs protection: aluminium foil facing, a coating, or a metal jacket. Without a jacket the surface degrades within a season or two.

What is the difference between Class B and Class 0?

Both are produced from the same formulation with the same thermal and moisture data; the designation follows the fire classification your market requires. The material itself is self-extinguishing with an oxygen index of at least 32 % and smoke density in the 25–50 range. Tell us the classification your authority or your customer's specification calls for and we produce to it — do not assume one market's class number means the same thing in another.

How is the tube packed and what is the standard length?

Standard length is 1.83 m per piece, packed in cartons of 1850 × 320 × 360 mm. Wall thickness and inside diameter decide how many pieces go into a carton, and that packing list goes out with the quotation.

Can you produce to our own specification?

Yes. Density is 65 kg/m³ as standard and can be produced from 55 to 90 kg/m³, wall thickness and colour are made to the customer's specification, and both adhesive-free and self-adhesive versions are available. Production figures are nominal and tested per batch, so the test report that accompanies the shipment is what your incoming inspection should be checked against.

One closed-cell system, from the chiller to the last metre of pipe

Send us your specification — we will price it within one working day

Send the inner diameter, wall thickness, class and quantity, or simply attach your BOQ. We quote FOB Shanghai as standard, EXW or CIF on request.