Compound tube (fluorocarbon covered) — DACELLFLEX
DACELLFLEX®

Compound tube (fluorocarbon covered)

NBR closed-cell core with a fluorocarbon fibre covering: anti-UV, anti-oxidation, waterproof, chemical-proof and abrasion resistant for outdoor and industrial lines.

  • Covering rated −10 °C to +180 °C
  • Peel strength ≥ 350 N/m
  • Burst ≥ 2.0 MPa
  • For UV-exposed and corrosive sites
Ask for a price on this item

Products — Compound tube (fluorocarbon covered)

PropertyClass BClass 0
same values
Cell structureClosed cell—
MaterialNBR core + fluorocarbon fibre—
Density65 kg/m³ standard · 55–90 kg/m³ to order—
Thermal conductivity λ at −20 / 0 / +40 °C0.030 / 0.032 / 0.037 W/(m·K)0.030 / 0.032 / 0.037 W/(m·K)
Water vapour permeability1.96 × 10⁻¹¹ g/(m·s·Pa)—
Moisture resistance factor μ≥ 10,000—
Oxygen index≥ 32 %—
Flammability / smoke densitySelf-extinguishing / smoke density 25–50—
Water absorption≤ 5 %—
Service temperature−57 °C to +125 °C—
Flexibility / ozone resistanceExcellent / no crack—
Covering temperature−10 °C to +180 °C
Peel strength≥ 350 N/m
Burst strength≥ 2.0 MPa
Tensile strengthLong. ≥1180 / Transv. ≥820 N/5cm

Values are nominal production figures, tested per batch. Density, wall thickness and colour are produced to the customer's specification.

— means the value is identical for Class B and Class 0.

Inner diameter 6–89 mm (1/4″–3-1/2″) · wall thickness 6–50 mm (1/4″–2″). Intermediate sizes produced on request.

Where the jacketed compound tube is used

A closed-cell NBR core with a fluorocarbon fibre covering: the core does the insulating, the covering takes the environment. Use it where the standard tube would fail at the surface rather than in the wall.

Outdoor pipework and roof-level runs

Ultraviolet is what destroys an unprotected foam surface, not temperature. The covering is rated to +180 °C and is formulated to resist UV and oxidation, which is what makes an outdoor run possible without a metal jacket.

Chemical and coastal environments

Where airborne chemical exposure, salt or wash-down would attack an exposed foam surface. The covering resists chemical attack and abrasion; the closed-cell core keeps the thermal performance.

Industrial lines with mechanical contact

Where pipework is climbed over, walked on or washed. The covering provides abrasion resistance at the surface while the core stays intact.

Where a jacket would be impractical

Metal cladding on small-bore or complex pipework is slow and expensive. A covered tube gives protection in one step, on bends and fittings as well as straight runs.

How to specify it

Three things to fix at enquiry, and one to check honestly:

Covering properties we publish: peel strength ≥ 350 N/m and burst ≥ 2.0 MPa (site data). These describe the covering's mechanical performance; they are not a fire classification and should not be read as one.

How the wall thickness is calculated →

Installation points that decide whether it works

Questions buyers ask before ordering

Can this replace a metal jacket outdoors?

On most outdoor runs, yes — the covering is formulated for UV, oxidation and abrasion, which is the job a metal jacket does. Where the specification demands a metal finish for impact or fire reasons, use metal; where the requirement is weather and UV, the covered tube is faster to install and cheaper on complex geometry.

What temperature can it take?

Covering: −10 °C to +180 °C. Core: −57 °C to +125 °C. The lower of the two governs, so the core is the limit on hot lines — above +125 °C this product is not the right choice and mineral wool is.

Is the covering a vapour barrier?

The vapour resistance comes from the closed-cell NBR core (μ ≥ 10,000). The covering's job is mechanical and environmental protection. Joints still need to be glued and taped, and ends sealed.

Do you have test data for the covering?

We publish peel strength ≥ 350 N/m and burst ≥ 2.0 MPa. If your specification asks for a particular test standard or a fire classification for the covering, send the clause and we will tell you exactly what we can and cannot document before you order.

One closed-cell system, from the chiller to the last metre of pipe

Send us your specification — we will price it within one working day

Send the inner diameter, wall thickness, class and quantity, or simply attach your BOQ. We quote FOB Shanghai as standard, EXW or CIF on request.